No. | Technical features | Descriptions | |
1 | Gantry | ||
1.01 | Gantry type | Low voltage slip-ring | |
1.02 | Gantry driven type | Strap-driven | |
1.03 | Patient opening | 70cm | |
1.04 | Gantry tilt mode | Digital gantry tilt | |
1.05 | Digital tilt capability | ±50° | |
1.06 | Detector type | OptiWave rare-earth ceramic detector | |
1.07 | Numbers of detector rows | 16 | |
1.08 | Width of Z-axle detector | 20mm | |
1.09 | Detector columns of channels per row | 848 | |
1.10 | Numbers of detector columns | 13568 | |
1.11 | Data-transfer type | RF, optical fiber communication | |
1.12 | Distance of focus-ISO-center | 53cm | |
1.13 | Distance of focus-detector | 94cm | |
1.14 | 3D laser orientation | Provided | |
1.15 | 13" integrated display panel | Provided | |
1.16 | Adose automatic exposure control (mA Modulation) | Provided | |
1.17 | Auto-voice manager | Breath Graphical Display Hold Message (Record/Playback) Breath Message (Record/Playback) |
|
1.18 | AccuSaving energy conservation management | Provided | |
2 | HVPS and X-ray tube | ||
2.01 | Maximum continuous output of HVgenerator | 42kW | |
2.02 | Tube kV selections | 70kV, 80kV, 100 kV, 120 kV, 140 kV | |
2.03 | Tube mA range | 10~350mA | |
2.04 | Tube anode heat capacity | 3.5MHU | |
2.05 | Max. anode cooling rate | 735kHU/min | |
2.06 | Type of cooling | Oil cooling + Air cooling | |
2.07 | Tube focus | Large: 1.2mm×1.4mm Small: 0.7mm×0.8mm |
|
2.08 | Collimator width selection | 4-level election | |
2.09 | Focus spot tracking technology | Provided | |
3 | Patient table | ||
3.01 | Maximum horizontal-movable range | 1850mm | |
3.02 | Table horizontal-scannablerange | 1200mm | |
3.03 | Table horizontal-position repeatability | ±0.25mm | |
3.04 | Minimum height above floor | 430mm | |
3.05 | Maximum vertical-movable range | 500mm | |
3.06 | Maximum speed of vertical movement | 35mm | |
3.07 | Maximum speed of horizontal movement | 150mm/s | |
3.08 | Maximum patient weight | 180kg | |
4 | Computer | ||
4.01 | CPU | 3.5GHz | |
4.02 | Memory | 32GB | |
4.03 | Storage of hard-disk | 1TB×2 | |
4.04 | Monitor | 24’’ LCD Monitor | |
4.05 | Resolution of monitor | 1920×1200 | |
4.06 | Image-data external storage type | CD/DVD/USB | |
4.07 | Time of image reconstruction (512×512) | 33.3ms/image | |
4.08 | Speed of image reconstruction (512×12) | 30fps | |
4.09 | DICOM 3.0 interface | Provided | |
4.10 | Printer DICOM 3.0 interface | Provided | |
4.11 | Auto filming | Provided | |
4.12 | Worklist function | Provided | |
5 | Scan parameters | ||
5.01 | Shortest 360 degree rotation time | 0.75s | |
5.02 | Allowed rotation times | 0.75s, 1.0s, 1.5s, 2.0s, 3.0s, 4.0s | |
5.03 | Maximum slice numbers per rotation | 32 | |
5.04 | Minimum slice thickness of scan | 1.25mm | |
5.05 | Minimum slice thickness of reconstruction | 0.625mm | |
5.06 | Maximum slice thickness of scan | 20mm | |
5.07 | Nominal reconstruction slice thickness | 0.625mm, 1.25mm, 2.5mm, 5.0mm, 7.5mm, 10mm, 20mm | |
5.08 | Speed of image reconstruction (512×512) | 30 frames/s | |
5.09 | Scan FOV | 50cm | |
5.10 | Image reconstruction matrix | 512×512, 1024×1024 (Optional) | |
5.11 | Image reconstruction matrix | 512×512, 1024×1024 (Optional) | |
5.12 | Image display matrix | 512×512, 1024×1024 (Optional) | |
5.13 | Maximum continuous scan duration | 120s | |
5.14 | Maximum continuous scan length | 180cm | |
5.15 | Direction of TOPO | Front-back, Left-right | |
5.16 | Max. length of TOPO | 180cm | |
5.17 | Range of pitch | 0.5~1.5 | |
5.18 | Scan mode | Scout scan Axial scan Helical scan Cine scan |
|
6 | Image Quality | ||
6.01 | High contrast resolution | 21lp/cm@0%MTF | |
6.02 | Low contrast resolution | 2.0mm@0.30% | |
6.03 | Isotropic imaging resolution | 0.24mm | |
6.04 | Range of CT numbers | -32767~32768 | |
6.05 | Image noise | ≤0.29@28mGy | |
7 | Advanced application | ||
7.01 | Multi-Planar Reconstruction (MPR) | Provided | |
7.02 | Curve Multi-Planar Reconstruction (CPR) | Provided | |
7.03 | Surface Shaded Display (SSD) | Provided | |
7.04 | Volume Rendering (VR) | Provided | |
7.05 | Maximum Intensity Projection (MIP) | Provided | |
7.06 | Minimum Intensity Projection (MinIP) | Provided | |
7.07 | Virtual Endoscopy (VE) | Provided | |
7.08 | CT angiography (CTA) | Provided | |
7.09 | Tissue segmentation | Provided | |
7.10 | One click bone remove | Provided | |
7.11 | One click patient table remove | Provided | |
7.12 | Bolus-tracking Technology | Provided | |
7.13 | Spiral auto start | Provided | |
7.14 | Cine display | Provided | |
7.15 | AbastTM bone artifact suppression technology | Provided | |
7.16 | AmastTM metal artifact suppression technology | Provided | |
7.17 | Admir3D all-domain iterative reconstruction | Provided | |
7.18 | Low-dose pediatric scan technology | Provided | |
7.19 | Low-dose lung scan technology | Provided | |
7.20 | AccuHead grey-white matter enhanced technology | Provided | |
7.21 | AccuOrgan lung high resolution scan technology | Provided | |
7.22 | AccuOrgan inner-ear high resolution scan technology | Provided | |
7.23 | AccuOrgan body high resolution scan technology | Provided | |
7.24 | AccuOrgan bone high resolution scan technology | Provided | |
7.25 | AccuMatter dual-energy with Admir3D for new application | Provided |